Some Info of 110 Patch Panel II


110 Patch Panel
incorporates a disadvantage that it can not be second protected, so it should be considered into the floor with the local installation with the flow, over-voltage protection device Patch Panel. You will discover five main distribution frame 110 termination hardware type. 110A type, 110P model, 110JP type, 110VP VisiPatch type and XLBET large. 110A, 110P, 110JP, 110VP VisiPatch and XLBET systems have a similar electrical performance, but its performance, specifications and field occupied because of the wall or panel dimension is different.

Each of the hardware
have their own advantages. 110A Patch Panel. 110A-type Patch Panel provides you with a number of pins, commonly known as "Patch Panels with 110 legs" 110A work extremely well for all occasions, especially for large telephone applications may also be used in an indirect line of wiring where space is fixed, because the number of lines 110A and 110P wiring underneath the same circumstances, 110A occupies half the room is 110P.

110A systems generally
employ a single connection to CCW-F jumper crosslinking, while the CCW-F jumper reached only three kinds of performance, which limits the performance on the system 110A jumper in the use of CCW can just achieve its level of three categories. But when you use 110A jumper can quickly fit performance to a number exceeding five or six.